{"_buckets": {"deposit": "509afa50-da5a-43ae-8b82-04b90ef863f3"}, "_deposit": {"id": "4899", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "4899"}, "status": "published"}, "_oai": {"id": "oai:teapot.lib.ocha.ac.jp:00004899", "sets": ["221"]}, "control_number": "4899", "item_12_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "82", "bibliographicPageStart": "75", "bibliographicVolumeNumber": "21", "bibliographic_titles": [{"bibliographic_title": "Journal of physiological anthropology and applied human science"}]}]}, "item_12_description_17": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_12_description_46": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "学術雑誌論文", "subitem_description_type": "Other"}]}, "item_12_description_6": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Abstract To alleviate worker\u0027s thermal discomfort in a moderately hot environment, a new cooling vest was designed and proposed in this paper. To investigate the effect of the cooling vest and to collect the knowledge for the design of comfortable cooling vest, subjective experiments were conducted. Two kinds of cooling vests, the new one and the commercially available one, were used for comparison. The new cooling vest had more insulation and its surface temperature was higher than the commercially available one. Experiments were performed in the climatic chamber where operative temperature was controlled at 3O.2℃ and relative humidity was at 37% under still air. In addition, experiment without cooling vest was carried out as a control condition. The results obtained in these experiments were as follow : 1) By wearing both types of cooling vest, the whole body thermal sensation was closer to the neutral conditions than those without cooling vest. This effect was estimated to be equal to the 5.7℃ decrement of operative temperature. The subjects felt more comfortable with the cooling vest than without it. They felt\\more thermally acceptable than that without cooling vest. Wearing the cooling vest was useful to decrease the sweating sensation. 2) The local discomfort was observed when the local thermal sensation was \"cool\"~\"cold\" with the cooling vest. 3) The new cooling vest kept the skin temperature at chest at about 32.6℃. On the other hand, by wearing the commercially available one, it lowered to about 31.1℃. By wearing the new cooling vest, there was a tendency that local thermal sensation vote was higher and local comfort sensation vote was more comfortable than those of the condition wearing the commercially available one. It is important for the design of a comfortable cooling garment to prevent over-cool down from the body.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_12_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本生理人類学会"}]}, "item_12_relation_54": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110002528544/", "subitem_relation_type_select": "URI"}}]}, "item_12_rights_14": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "日本生理人類学会"}, {"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}]}, "item_12_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_12_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11462444", "subitem_source_identifier_type": "NCID"}]}, "item_12_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13453475", "subitem_source_identifier_type": "ISSN"}]}, "item_12_subject_20": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "460", "subitem_subject_scheme": "NDC"}]}, "item_12_text_18": {"attribute_name": "形態", "attribute_value_mlt": [{"subitem_text_value": "996616 bytes"}]}, "item_12_text_47": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "学術雑誌論文"}]}, "item_12_text_48": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Journal Article"}]}, "item_12_text_49": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_12_text_50": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "01"}]}, "item_12_text_79": {"attribute_name": "所属", "attribute_value_mlt": [{"subitem_text_value": "Department of Human Environmental Engineering, Ochanomizu University"}, {"subitem_text_value": "Department of Architecture, Waseda University"}, {"subitem_text_value": "Graduate School of Engineering, Hokkaido University"}, {"subitem_text_value": "NTT FACILITIES"}]}, "item_1622774516477": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nishihara, Naoe"}], "nameIdentifiers": [{"nameIdentifier": "89023", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanabe, Shin-ichi"}], "nameIdentifiers": [{"nameIdentifier": "89024", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hayama, Hirofumi"}], "nameIdentifiers": [{"nameIdentifier": "89025", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Komatsu, Masayoshi"}], "nameIdentifiers": [{"nameIdentifier": "89026", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-04-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "J of physiological anthropology and applied human science21(1)_nishihara.pdf", "filesize": [{"value": "996.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 996600.0, "url": {"label": "J of physiological anthropology and applied human science21(1)_nishihara.pdf", "url": "https://teapot.lib.ocha.ac.jp/record/4899/files/J of physiological anthropology and applied human science21(1)_nishihara.pdf"}, "version_id": "6fadd282-68ba-45a2-8109-50c9d556692b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "cooling vest", "subitem_subject_scheme": "Other"}, {"subitem_subject": "thermal sensation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "thermal comfort", "subitem_subject_scheme": "Other"}, {"subitem_subject": "climatic chamber", "subitem_subject_scheme": "Other"}, {"subitem_subject": "subjective experiment", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A Cooling Vest for Working Comfortably in a moderately Hot Environment", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A Cooling Vest for Working Comfortably in a moderately Hot Environment", "subitem_title_language": "en"}]}, "item_type_id": "12", "owner": "17", "path": ["221"], "permalink_uri": "http://hdl.handle.net/10083/1822", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2008-03-17"}, "publish_date": "2008-03-17", "publish_status": "0", "recid": "4899", "relation": {}, "relation_version_is_last": true, "title": ["A Cooling Vest for Working Comfortably in a moderately Hot Environment"], "weko_shared_id": -1}
  1. その他のコレクション
  2. NDC
  3. 4 自然科学

A Cooling Vest for Working Comfortably in a moderately Hot Environment

http://hdl.handle.net/10083/1822
http://hdl.handle.net/10083/1822
01e0f948-26c9-411d-b659-9e3a536b9644
名前 / ファイル ライセンス アクション
J J of physiological anthropology and applied human science21(1)_nishihara.pdf (996.6 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-03-17
タイトル
言語 en
タイトル A Cooling Vest for Working Comfortably in a moderately Hot Environment
言語
言語 eng
キーワード
主題Scheme Other
主題 cooling vest
キーワード
主題Scheme Other
主題 thermal sensation
キーワード
主題Scheme Other
主題 thermal comfort
キーワード
主題Scheme Other
主題 climatic chamber
キーワード
主題Scheme Other
主題 subjective experiment
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Nishihara, Naoe

× Nishihara, Naoe

WEKO 89023

Nishihara, Naoe

Search repository
Tanabe, Shin-ichi

× Tanabe, Shin-ichi

WEKO 89024

Tanabe, Shin-ichi

Search repository
Hayama, Hirofumi

× Hayama, Hirofumi

WEKO 89025

Hayama, Hirofumi

Search repository
Komatsu, Masayoshi

× Komatsu, Masayoshi

WEKO 89026

Komatsu, Masayoshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract To alleviate worker's thermal discomfort in a moderately hot environment, a new cooling vest was designed and proposed in this paper. To investigate the effect of the cooling vest and to collect the knowledge for the design of comfortable cooling vest, subjective experiments were conducted. Two kinds of cooling vests, the new one and the commercially available one, were used for comparison. The new cooling vest had more insulation and its surface temperature was higher than the commercially available one. Experiments were performed in the climatic chamber where operative temperature was controlled at 3O.2℃ and relative humidity was at 37% under still air. In addition, experiment without cooling vest was carried out as a control condition. The results obtained in these experiments were as follow : 1) By wearing both types of cooling vest, the whole body thermal sensation was closer to the neutral conditions than those without cooling vest. This effect was estimated to be equal to the 5.7℃ decrement of operative temperature. The subjects felt more comfortable with the cooling vest than without it. They felt\more thermally acceptable than that without cooling vest. Wearing the cooling vest was useful to decrease the sweating sensation. 2) The local discomfort was observed when the local thermal sensation was "cool"~"cold" with the cooling vest. 3) The new cooling vest kept the skin temperature at chest at about 32.6℃. On the other hand, by wearing the commercially available one, it lowered to about 31.1℃. By wearing the new cooling vest, there was a tendency that local thermal sensation vote was higher and local comfort sensation vote was more comfortable than those of the condition wearing the commercially available one. It is important for the design of a comfortable cooling garment to prevent over-cool down from the body.
言語 en
書誌情報 Journal of physiological anthropology and applied human science

巻 21, 号 1, p. 75-82, 発行日 2002-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 13453475
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11462444
権利
権利情報 日本生理人類学会
権利
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである
フォーマット
内容記述タイプ Other
内容記述 application/pdf
形態
996616 bytes
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
著者版フラグ
値 publisher
日本十進分類法
主題Scheme NDC
主題 460
出版者
出版者 日本生理人類学会
資源タイプ
内容記述タイプ Other
内容記述 学術雑誌論文
資源タイプ・ローカル
学術雑誌論文
資源タイプ・NII
Journal Article
資源タイプ・DCMI
text
資源タイプ・ローカル表示コード
01
異版である
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://ci.nii.ac.jp/naid/110002528544/
所属
Department of Human Environmental Engineering, Ochanomizu University
所属
Department of Architecture, Waseda University
所属
Graduate School of Engineering, Hokkaido University
所属
NTT FACILITIES
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 17:46:03.250951
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3